Description
Operating Temperature
50°C to 1200°C
Heating Medium
Electric Furnace Element Kanthal AF heaters provide years of trouble free service. Heater coil are installed on furnace wall to maximize heat transfer and temperature uniformity.
Input Voltage
Standard: 415V/3 Phase /50Hz
Control System
Our standard control package includes a single set-point temperature controller and additional safety cut-off/over-limit controller. Circulation fan/exhaust fan and heaters are electrically interlocked for safety to protect the heaters. All controls are housed in a IP65 enclosure. Controls are wired to SS638 Code of Practice for Electrical Installation standards.
Temperature Audit/Calibration: Third party Singlas certifications available for temperature controller/sensor calibration and 9 points temperature uniformity test.
Optional:
Door Limit Switch
Disables heater when oven door is opened.
Batch Timer
Adjustable up to 999 hrs., includes illuminated display to indicate timer operation and audible alarm when time has expired.
Ramp/ Soak Controller
Programmable ramp/ soak temperature controller with capability to store different up to 99 programs with multiple segments.
Chart Recorder
Single channel/Multiple channels paperless chart recorder for continuous monitoring of temperature data. Comes with Type “K” thermocouple input. Allows downloading of digital data files through USB or Ethernet connection. Data can also be viewed on a full color display or on a web server when connected to a network.